Flexible multicore twist pair shield CAT5A elevator flat travel cable

Flat travelling cable is mainly used in power supply, control system, data transmission system and video signal transmission system for variously civil elevators or industrial lifts. Such as urban buildings, railway system, airports, shopping malls, construction sites etc.

Category
Cable Specifications

Application

These flat cables can be used on festooned systems on handling equipment as overhead cranes,

also can be used for cargo or manned elevators as power and control cable.

They are designed for indoors and outdoors for ambient temperature down to -25°C.

These cables can accept a trolley traveling speed up to 120m / min.

Standard

HD 359 S2,

IEC 227 Part 6,

EN 50214

Cable Construction

1. Conductor: Flexible Bare copper class 6 or tinned copper

2. Insulation: Special Rubber compound/NBR-PVC /PE /on request

3. Shield: Tinned copper braid / aluminum foil/ on request (optional)

4. Sheath: Special Rubber compound/ NBR-PVC /PUR(TPU)/on request

5. Reinforce: steel wires (optional)

6. Twist: Group twisted

7. Color: Black, Yellow, Grey, or on request

Technical Date​​​​

Type

Conductor

Conductor

Overall diameter

70℃ Insulated Resister

20℃ Conductor DC Resister

 

Section(mm2)

Construction(mm2)

Dia.(mm)

(M Ω·KM)

(Ω/KM)

TVVB

20×0.75

30/0.18

29.9×9.0

≥0.011

≤26.0

TVVB

20×0.75

30/0.18

30.5×9.1

≥0.011

≤26.0

TVVBG

2×1.0+TV(SYV75-4)

7/0.24+50/0.16

15.8×7.6

≥0.010

≤19.5

TVVB

20×0.75+(2×2)×0.75

30/0.18

44.2×9.1

≥0.011

≤26.0

TVVB

36×0.75+(2×2)×0.75

30/0.18

62×10.0

≥0.011

≤26.0

TVVB

48×0.75+(2×2)×0.75

30/0.18

68.5×10.0

≥0.011

≤26.0

TVVBG

30×0.75

30/0.18

53×8.6

≥0.011

≤26.0

TVVBG

36×0.75

30/0.18

54.0×9.5

≥0.011

≤26.0

TVVBG

40×0.75

30/0.18

58×8.2

≥0.011

≤26.0

TVVBG

42×0.75

30/0.18

66.6×9.7

≥0.011

≤26.0

TVVBG

48×0.75

30/0.18

67.2×9.5

≥0.011

≤26.0

TVVBG

60×0.75

30/0.18

80.0×9.5

≥0.011

≤26.0

TVVB

30×0.75

30/0.18

44.2×9.1

≥0.011

≤26.0

TVVB

36×0.75

30/0.18

42.5×9.0

≥0.011

≤26.0

TVVB

40×0.75

30/0.18

5.25×9.0

≥0.011

≤26.0

TVVB

42×0.75

30/0.18

54.1×9.7

≥0.011

≤26.0

TVVB

48×0.75

30/0.18

58.0×9.6

≥0.011

≤26.0

Type

Conductor

Overall diameter

70℃
Insulated Resister

 

Construction
(mm2)

Dia.
(mm)

(M Ω·KM)

TVVB

30/0.18

29.9×9.0

≥0.011

TVVB

30/0.18

30.5×9.1

≥0.011

TVVBG

7/0.24
+50/0.16

15.8×7.6

≥0.010

TVVB

30/0.18

44.2×9.1

≥0.011

TVVB

30/0.18

62×10.0

≥0.011

TVVB

30/0.18

68.5×10.0

≥0.011

TVVBG

30/0.18

53×8.6

≥0.011

TVVBG

30/0.18

54.0×9.5

≥0.011

TVVBG

30/0.18

58×8.2

≥0.011

TVVBG

30/0.18

66.6×9.7

≥0.011

TVVBG

30/0.18

67.2×9.5

≥0.011

TVVBG

30/0.18

80.0×9.5

≥0.011

TVVB

30/0.18

44.2×9.1

≥0.011

TVVB

30/0.18

42.5×9.0

≥0.011

TVVB

30/0.18

5.25×9.0

≥0.011

TVVB

30/0.18

54.1×9.7

≥0.011

TVVB

30/0.18

58.0×9.6

≥0.011

Electric Parameter

Conductor Standard: IEC VDE0295, CLASS 6  

Min. bending radius: 5-10 x outer diameter 

Temperature: 15 to 70 on request

Normal Voltage: 300/500V /450/750V

Test Voltage: 3500V-5000V

Max.Conductor DC Resistance at 20℃(Ω/KM): 26

Min.Insulation DC Resistance at 70℃(MΩ/KM): 0.012

Advantages:  flexible, flame retardant, low smoke halogen free, good data transmission, power supply, abrasion resistance, tension resistance, etc.