TSFLCGEWOEU Medium voltage flat reeling cable

The Medium voltage flat reeling cable as power supply with reinforced PUR sheath is very suitable for high and extreme mechanical stress used wherever cable operation requires frequent reeling and unreeling on pulleys, drums or rollers indoors or outdoors in wet or dry conditions. Such as Ship to Shore Cranes, Rail Mounted Gantry Cranes and other heavy mobile equipment

Cable Specifications
flat-reeling-cable

Construction

  1. Conductor: Extra fine bare copper conductor class 6 VDE 0295
  2. Insulation: Special rubber compound based on NBR
  3. Reinforce: Protective earth conductor Individually braid of tinned copper wires
  4. Core: Fiber optics / control cores
  5. Advantages: Outer sheath PUR resistant to tearing, notching and abrasion

Technical Date​

Specification
(mm2)
Overall diameter
(mm)
Approx weight
(kg/m)
Tensile  Load
(N)
Current at 30℃
(A)
Max. resistance of
 the Current at 30℃
(Ω/KW)
Voltagedrop 
per 100m
(V)
3*35+1*16+12FO69.2*15.92.21020571550.57617.86
3*50+1*25+12FO82.7*18.53.111 2973 175 0.40114.04 
3*70+1*35+12FO92.6*20.64.053 4165 220 0.28312.45 
3*95+1*50+12FO108*22.75.349 5695 260 0.21411.13 
3*120+1*70+12FO121.7*26.97.015 7310 320 0.16710.69 
3*150+1*70+12FO130.9*298.342 8842 385 0.13410.32 
3*185+1*95+12FO149.4*32.310.476 11049 430 0.119.46 
3*240+1*120+12FO164.7*37.313.460 14281 535 0.08338.91 
3*35+2*16+12FO80.5*162.547 2329 155 0.57617.86 
3*50+2*25+12FO94*18.53.547 3398 175 0.40114.04 
3*70+2*35+12FO104.8*20.64.610 4760 220 0.28312.45 
3*95+2*50+12FO121.9*22.76.087 6544 260 0.21411.13 
3*120+2*70+12FO134.8*26.97.933 8500 320 0.16710.69 
3*150+2*70+12FO142.9*299.254 10032 385 0.13410.32 
3*185+2*95+12FO162.8*32.311.667 12664 430 0.119.46 
3*240+2*120+12FO177.5*37.314.876 16321 535 0.08338.91 
Specification
(mm2)
Overall diameter
(mm)
Approx weight
(kg/m)
Tensile  Load
(N)
Current at 30℃
(A)
Max. resistance of
 the Current at 30℃
(Ω/KW)
Voltagedrop 
per 100m
(V)
3*35+12*2.5+12FO88*162.57922941550.57617.86
3*50+12*2.5+12FO97*18.53.362 3058 175 0.40114.04 
3*70+12*2.5+12FO93.3*20.63.909 4079 220 0.28312.45 
3*95+12*2.5+12FO102.5*22.74.914 5354 260 0.21411.13 
3*120+12*2.5+12FO112.9*26.96.299 6629 320 0.16710.69 
3*150+16*2.5+12FO123.4*297.695 8161 385 0.13410.32 
3*185+19*2.5+12FO140.2*32.39.540 9943 430 0.119.46 
3*240+24*2.5+12FO153.3*37.312.284 12750 535 0.08338.91 

Technical Info

Working voltage: 3.6/6KV

Test Voltage: 12.5 kV AC (5 Min.)

Working temperature: Fixed:-50-125℃    Remove: -30-125℃

Bending radius: Fixed: 6*thickness of cable  Flexing: 10* thickness of cable