PUR Lifting Cable Reel Cable with galvanized steel rope support

Pur jacket cable is suitable for mobile equipment such as fast running container crane, lifting equipment, large equipment, excavator, ground and underground mining, etc. It has long service life but stable quality. The high rank rubber material is more wear-resistant and resistant to harsh environment. The conductor is tinned copper wire, which reduces oxidation phenomenon and increases service life.

Cable Specifications

Construction

  • Conductor : Extra fine bare copper conductor class 6 VDE 0295
  • Insulation: Rubber compound based on NBR 
  • Outer Jacket: PUR/Special rubber compound based on NBR/others
  • Jacket Color: Black, Yellow, Red, Gray…etc customized
  • Support Element: Galvanized steel rope
  • Other Structure Can Be Customized As Your Need

Technical Date​​

Specification
(mm2)
Overall diameter
(mm)
Approx weight
(kg/m)
Tensile  Load
(N)
Current at 30℃
(A)
Max. resistance of
 the Current at 30℃
(Ω/KW)
Voltagedrop 
per 100m
(V)
3*16+2*10 57*111.27029871051.25826.42
3*25+2*1063.8*13.21.740 4337 135 0.81121.90 
3*35+2*1673.1*15.22.366 5194 168 0.57619.35 
3*50+2*2585.6*17.63.297 6478 206 0.40116.52 
3*70+2*3598.8*19.64.439 11712 255 0.28314.43 
3*95+2*50114.6*21.65.843 13853 318 0.21413.61 
3*120+2*70126.6*25.67.580 16201 385 0.16712.86 
3*150+2*70134.2*27.68.833 18039 452 0.13412.11 
3*185+2*95156.8*30.811.370 27197 510 0.1111.22 
3*240+2*120170.3*35.514.419 31585 606 0.083310.10 

Electrical Performance​​​​​

Voltage: 0.6/1kv customized

Test Voltage: 3.5kv/5min (AC)

Bending Radius & Temperature Range​​​​​​​​

Fixed Installation: 5 * cable outer diameter

Mobile Installation: 6-10 * cable outer diameter

Fixed Installation: – 40 ℃ ~ 120℃

Mobile Installation: – 30 ℃ ~ 90 ℃